Tomi Valkeinen authored
Commit f476ae9d (OMAPDSS: APPLY: Remove DISPC writes to manager's lcd parameters in interface) broke the SDI output, as it causes the SDI PLL locking to fail. LCLK and PCLK divisors are located in shadow registers, and we normally write them to DISPC registers when enabling the output. However, SDI uses pck-free as source clock for its PLL, and pck-free is affected by the divisors. And as we need the PLL before enabling the output, we need to write the divisors early. It seems just writing to the DISPC register is enough, and we don't need to care about the shadow register mechanism for pck-free. The exact reason for this is unknown. Signed-off-by: Tomi Valkeinen <tomi.valkeinen@ti.com> Reported-by: Aaro Koskinen <aaro.koskinen@iki.fi> Signed-off-by: Florian Tobias Schandinat <FlorianSchandinat@gmx.de>
35d67866