Kurt Garloff authored
Some devices report a peripheral qualifier of 3 for LUN 0; with the original code, we would still try a REPORT_LUNS scan (if SCSI level is >= 3 or if we have the BLIST_REPORTLUNS2 passed in), but NOT any sequential scan. Also, the device at LUN 0 (which is not connected according to the PQ) is not registered with the OS. Unfortunately, SANs exist that are SCSI-2 and do NOT support REPORT_LUNS, but report a unknown device with PQ 3 on LUN 0. We still need to scan them, and most probably we even need BLIST_SPARSELUN (and BLIST_LARGELUN). See the bug reference for an infamous example. This is patch 1/3: If we end up in sequential scan, at least try LUN 1 for devices that reported a PQ of 3 for LUN 0. Also return blacklist flags, even for PQ3 devices. Signed-off-by: Kurt Garloff <garloff@suse.de> Signed-off-by: James Bottomley <James.Bottomley@SteelEye.com>
4186ab19