Sherry Sun authored
When the user initializes the uart port, and waits for the transmit engine to complete in lpuart32_set_termios(), if the UART TX fifo has dirty data and the UARTMODIR enable the flow control, the TX fifo may never be empty. So here we should disable the flow control first to make sure the transmit engin can complete. Fixes: 380c966c ("tty: serial: fsl_lpuart: add 32-bit register interface support") Cc: stable <stable@kernel.org> Signed-off-by: Sherry Sun <sherry.sun@nxp.com> Link: https://lore.kernel.org/r/20220821101527.10066-1-sherry.sun@nxp.comSigned-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
d5a2e083