Vignesh R authored
commit 6ac734d2 upstream. After enabling and disabling ADC continuous mode via sysfs, ts_print_raw fails to return any data. This is because when ADC is configured for continuous mode, it disables touch screen steps.These steps are not re-enabled when ADC continuous mode is disabled. Therefore existing values of REG_SE needs to be cached before enabling continuous mode and disabling touch screen steps and enabling ADC steps. The cached value are to be restored to REG_SE once ADC is disabled. Fixes: 7ca6740c ("mfd: input: iio: ti_amm335x: Rework TSC/ADC synchronization") Signed-off-by: Vignesh R <vigneshr@ti.com> Signed-off-by: Lee Jones <lee.jones@linaro.org> Signed-off-by: Luis Henriques <luis.henriques@canonical.com>