Guenter Roeck authored
Commit b50aa496 ("hwmon: (lm90) Prevent integer underflows of temperature calculations") addressed a number of underflow situations when writing temperature limits. However, it missed one situation, seen when an attempt is made to set the hysteresis value to MAX_LONG and the critical temperature limit is negative. Use clamp_val() when setting the hysteresis temperature to ensure that the provided value can never overflow or underflow. Fixes: b50aa496 ("hwmon: (lm90) Prevent integer underflows of temperature calculations") Cc: Dmitry Osipenko <digetx@gmail.com> Reviewed-by:
Dmitry Osipenko <digetx@gmail.com> Signed-off-by:
Guenter Roeck <linux@roeck-us.net>
55840b9e