Icenowy Zheng authored
The PLLs on H3 have a lock bit, which will only be set to 1 when the PLL is really working. Add CLK_SET_RATE_UNGATE to the PLLs, otherwise it will timeout when trying to set PLL clock frequency without enabling it. Fixes: 0577e485 ("clk: sunxi-ng: Add H3 clocks") Signed-off-by: Icenowy Zheng <icenowy@aosc.io> Signed-off-by: Maxime Ripard <maxime.ripard@free-electrons.com>