Under some circumstances, firmware in the QAT devices could become unresponsive. The Heartbeat feature provides a mechanism to detect unresponsive devices. The QAT FW periodically writes to memory a set of counters that allow to detect the liveness of a device. This patch adds logic to enable the reporting of those counters, analyze them and report if a device is alive or not. In particular this adds (1) heartbeat enabling, reading and detection logic (2) reporting of heartbeat status and configuration via debugfs (3) documentation for the newly created sysfs entries (4) configuration of FW settings related to heartbeat, e.g. tick period (5) logic to convert time in ms (provided by the user) to clock ticks This patch introduces a new folder in debugfs called heartbeat with the following attributes: - status - queries_sent - queries_failed - config All attributes except config are reading only. In particular: - `status` file returns 0 when device is operational and -1 otherwise. - `queries_sent` returns the total number of heartbeat queries sent. - `queries_failed` returns the total number of heartbeat queries failed. - `config` allows to adjust the frequency at which the firmware writes counters to memory. This period is given in milliseconds and it is fixed for GEN4 devices. Signed-off-by: Damian Muszynski <damian.muszynski@intel.com> Reviewed-by: Giovanni Cabiddu <giovanni.cabiddu@intel.com> Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Signed-off-by: Herbert Xu <herbert@gondor.apana.org.au>