David Daney authored
Define two new "compatible" values for Ethernet PHYs. "ethernet-phy-ieee802.3-c22" and "ethernet-phy-ieee802.3-c45" are used to indicate a PHY uses the corresponding protocol. If a PHY is "compatible" with "ethernet-phy-ieee802.3-c45", we indicate this so that get_phy_device() can properly probe the device. If get_phy_device() fails, it was probably due to failing the probe of the PHY identifier registers. Since we have the device tree telling us the PHY exists, go ahead and add it anyhow with a phy_id of zero. There may be a driver match based on the "compatible" property. Signed-off-by: David Daney <david.daney@cavium.com> Signed-off-by: David S. Miller <davem@davemloft.net>
6bd47ac2