-
Lokesh Vutla authored
Write to trigger register(OMAP_TIMER_TRIGGER_REG) will load the value in Load register(OMAP_TIMER_LOAD_REG) into Counter register (OMAP_TIMER_COUNTER_REG). omap_dm_timer_set_load() writes into trigger register every time load register is updated. When timer is configured in pwm mode, this causes disruption in current pwm cycle, which is not expected especially when pwm is used as PPS signal for synchronized PTP clocks. So do not write into trigger register on updating the period. Signed-off-by: Lokesh Vutla <lokeshvutla@ti.com> Tested-by: Tony Lindgren <tony@atomide.com> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Link: https://lore.kernel.org/r/20200224050753.17784-3-lokeshvutla@ti.com
6ce4fcb0