• Oleksij Rempel's avatar
    regulator: dt-bindings: Add 'regulator-uv-less-critical-window-ms' property · 759e2bd9
    Oleksij Rempel authored
    Introduces a new devicetree property to specifies the time window (in
    milliseconds) following a critical under-voltage (UV) event during which
    less critical actions can be safely carried out by the system.
    
    Less Critical Actions:
    - Logging the under-voltage event for later analysis.
    - Saving less critical data that may be useful for diagnosing issues or
      for audit purposes.
    
    More Critical Actions (post the less critical window):
    - Initiating procedures to properly shutdown hardware to prevent damage.
    
    The 'regulator-uv-less-critical-window-ms' property is crucial for
    conveying board-specific hardware characteristics, not for enforcing a
    certain policy. The time window represented by this property is derived
    from the physical attributes of the hardware like the capacity of
    on-board capacitors, the power consumption of the components, and the
    time needed to safely shut down hardware to prevent damage. These
    attributes can significantly vary between different boards, making it a
    board-specific property rather than a policy directive.
    
    By providing a precise representation of the time available for less
    critical actions post an under-voltage event, this property enables the
    kernel to make informed decisions on action prioritization, ensuring
    that essential preventative measures are taken to avoid hardware damage
    while also allowing for data capture and analysis.
    Signed-off-by: default avatarOleksij Rempel <o.rempel@pengutronix.de>
    Acked-by: default avatarRob Herring <robh@kernel.org>
    Link: https://lore.kernel.org/r/20231026144824.4065145-5-o.rempel@pengutronix.deSigned-off-by: default avatarMark Brown <broonie@kernel.org>
    759e2bd9