-
David Ertman authored
Several customers have reported a link flap issue on 82579. The symptoms are random and intermittent link losses when 82579 is connected to specific link partners. Issue has been root caused as interoperability problem between 82579 and at least some Broadcom PHYs in the Energy Efficient Ethernet wake mechanism. To fix the issue, we are disabling the Phase Locked Loop shutdown in 100M Low Power Idle. This solution will cause an increase of power in 100M EEE link. It will cost additional 28mW in this specific mode. Cc: Lukasz Adamczuk <lukasz.adamczuk@intel.com> Signed-off-by: Dave Ertman <davidx.m.ertman@intel.com> Tested-by: Aaron Brown <aaron.f.brown@intel.com> Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
7142a55c