Steffen Trumtrar authored
VCCR is used as a trigger to start voltage transitions, so we need to mark it volatile in order to make sure it gets written to hardware every time we set a new voltage. Fixes regulator voltage being stuck at the first voltage set after driver load. [lst: reworded commit message] Signed-off-by: Steffen Trumtrar <s.trumtrar@pengutronix.de> Signed-off-by: Lucas Stach <l.stach@pengutronix.de> Signed-off-by: Mark Brown <broonie@kernel.org> Cc: stable@vger.kernel.org