The PCM OSS mulaw plugin has a check of the format of the counter part whether it's a linear format. The check is with snd_BUG_ON() that emits WARN_ON() when the debug config is set, and it confuses syzkaller as if it were a serious issue. Let's drop snd_BUG_ON() for avoiding that. While we're at it, correct the error code to a more suitable, EINVAL. Reported-by: syzbot+23b22dc2e0b81cbfcc95@syzkaller.appspotmail.com Cc: <stable@vger.kernel.org> Link: https://lore.kernel.org/r/20200901131802.18157-1-tiwai@suse.deSigned-off-by: Takashi Iwai <tiwai@suse.de>
949a1ebe