Lukasz Luba authored
The SCMI v3.1 adds support for power values in micro-Watts. They are not always in milli-Watts anymore (ignoring the bogo-Watts). Thus, the power must be converted conditionally before sending to Energy Model. Add the logic which handles the needed checks and conversions. Acked-by: Sudeep Holla <sudeep.holla@arm.com> Signed-off-by: Lukasz Luba <lukasz.luba@arm.com> Acked-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
f3ac888f