Jaganath Kanakkassery authored
This implements Set extended scan param and set extended scan enable commands and use it for start LE scan based on controller support. The new features added in these commands are setting of new PHY for scanning and setting of scan duration. Both features are disabled for now, meaning only 1M PHY is set and scan duration is set to 0 which means that scanning will be done untill scan disable is called. < HCI Command: LE Set Extended Scan Parameters (0x08|0x0041) plen 8 Own address type: Random (0x01) Filter policy: Accept all advertisement (0x00) PHYs: 0x01 Entry 0: LE 1M Type: Active (0x01) Interval: 11.250 msec (0x0012) Window: 11.250 msec (0x0012) > HCI Event: Command Complete (0x0e) plen 4 LE Set Extended Scan Parameters (0x08|0x0041) ncmd 1 Status: Success (0x00) < HCI Command: LE Set Extended Scan Enable (0x08|0x0042) plen 6 Extended scan: Enabled (0x01) Filter duplicates: Enabled (0x01) Duration: 0 msec (0x0000) Period: 0.00 sec (0x0000) > HCI Event: Command Complete (0x0e) plen 4 LE Set Extended Scan Enable (0x08|0x0042) ncmd 2 Status: Success (0x00) Signed-off-by: Jaganath Kanakkassery <jaganathx.kanakkassery@intel.com> Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
a2344b9e