Anssi Hannula authored
With 0bfd:0124 Kvaser Mini PCI Express 2xHS FW 4.18.778 it was observed that if the device was bus-off when stopped, at next start (either via interface down/up or manual bus-off restart) the initial CMD_CHIP_STATE_EVENT received just after CMD_START_CHIP_REPLY will have the M16C_STATE_BUS_OFF bit still set, causing the interface to immediately go bus-off again. The bit seems to internally clear quickly afterwards but we do not get another CMD_CHIP_STATE_EVENT. Fix the issue by ignoring any initial bus-off state until we see at least one bus-on state. Also, poll the state periodically until that occurs. It is possible we lose one actual immediately occurring bus-off event here in which case the HW will auto-recover and we see the recovery event. We will then catch the next bus-off event, if any. This issue did not reproduce with 0bfd:0017 Kvaser Memorator Professional HS/HS FW 2.0.50. Fixes: 71873a9b ("can: kvaser_usb: Add support for more Kvaser Leaf v2 devices") Tested-by: Jimmy Assarsson <extja@kvaser.com> Signed-off-by: Anssi Hannula <anssi.hannula@bitwise.fi> Signed-off-by: Jimmy Assarsson <extja@kvaser.com> Link: https://lore.kernel.org/all/20221010185237.319219-9-extja@kvaser.comSigned-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
abb86709