Jarkko Nikula authored
If there is a signal pending and wait_for_completion_interruptible_timeout terminates with -ERESTARTSYS, we return and disable the i2c clocks in omap_i2c_xfer. If we terminate before sending last i2c message with a stop condition, the bus remains busy and we are not able to send new messages into bus with successive omap_i2c_xfer calls. Therefore a pending signal is not caught here and we return only because of timeout or i2c error. Signed-off-by: Jarkko Nikula <jarkko.nikula@nokia.com> Signed-off-by: Juha Yrjola <juha.yrjola@solidboot.com> Signed-off-by: Tony Lindgren <tony@atomide.com>