Paloma Arellano authored
DP controller can be setup to operate in either SDP update flush mode or peripheral flush mode based on the DP controller hardware version. Starting in DP v1.2, the hardware documents require the use of peripheral flush mode for SDP packets such as PPS OR VSC SDP packets. In-line with this guidance, lets program the DP controller to use peripheral flush mode starting DP v1.2 Changes in v4: - Clear up that DP_MAINLINK_CTRL_FLUSH_MODE register requires the use of bits [24:23] - Modify macros DP_MAINLINK_FLUSH_MODE_UPDATE_SDP and DP_MAINLINK_FLUSH_MODE_SDP_PERIPH_UPDATE to explicitly set their values in the bits of DP_MAINLINK_CTRL_FLUSH_MODE_MASK Changes in v3: - Clear up that the DP_MAINLINK_FLUSH_MODE_SDE_PERIPH_UPDATE macro is setting bits [24:23] to a value of 3 Changes in v2: - Use the original dp_catalog_hw_revision() function to correctly check the DP HW version Signed-off-by: Paloma Arellano <quic_parellan@quicinc.com> Reviewed-by: Dmitry Baryshkov <dmitry.baryshkov@linaro.org> Patchwork: https://patchwork.freedesktop.org/patch/579621/ Link: https://lore.kernel.org/r/20240222194025.25329-16-quic_parellan@quicinc.comSigned-off-by: Dmitry Baryshkov <dmitry.baryshkov@linaro.org>
21497a46