• Catalin Popescu's avatar
    net: phy: dp83826: support TX data voltage tuning · d1d77120
    Catalin Popescu authored
    DP83826 offers the possibility to tune the voltage of logical
    levels of the MLT-3 encoded TX data. This is useful when there
    is a voltage drop in between the PHY and the connector and we
    want to increase the voltage levels to compensate for that drop.
    
    Prior to PHY configuration, the driver SW resets the PHY which has
    the same effect as the HW reset pin according to the datasheet.
    Hence, there's no need to force update the VOD_CFG registers to make
    sure they hold their reset values. VOD_CFG registers need to be
    updated only if the DT has been configured with values other than
    the reset ones.
    Reviewed-by: default avatarAndrew Lunn <andrew@lunn.ch>
    Signed-off-by: default avatarCatalin Popescu <catalin.popescu@leica-geosystems.com>
    Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>