Robert Hancock authored
The axienet_start_xmit function was updating the tx_bd_tail variable multiple times, with potential rollbacks on error or invalid intermediate positions, even though this variable is also used in the TX completion path. Use READ_ONCE where this variable is read and WRITE_ONCE where it is written to make this update more atomic, and move the write before the MMIO write to start the transfer, so it is protected by that implicit write barrier. Signed-off-by: Robert Hancock <robert.hancock@calian.com> Signed-off-by: David S. Miller <davem@davemloft.net>