Daniel Lezcano authored
In order to set the scene for the thresholds support which have to manipulate the low and high temperature boundaries for the interrupt support, we must pass the low and high values to the incoming thresholds routine. The variables are set from the thermal_zone_set_trips() where the function loops the thermal trips to figure out the next and the previous temperatures to set the interrupt to be triggered when they are crossed. These variables will be needed by the function in charge of handling the thresholds in the incoming changes but they are local to the aforementioned function thermal_zone_set_trips(). Move the low and high boundaries computation out of the function in thermal_zone_device_update() so they are accessible from there. The positive side effect is they are computed in the same loop as handle_thermal_trip(), so we remove one loop. Co-developed-by: Rafael J. Wysocki <rjw@rjwysocki.net> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Link: https://patch.msgid.link/20240816081241.1925221-2-daniel.lezcano@linaro.orgSigned-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
f9ba1e05