James Smart authored
Fix a crash caused by a double put on the node when the driver completed an ACC for an unsolicted abort on the same node. The second put was executed by lpfc_nlp_not_used() and is wrong because the completion routine executes the nlp_put when the iocbq was released. Additionally, the driver is issuing a LOGO then immediately calls lpfc_nlp_set_state to put the node into NPR. This call does nothing. Remove the lpfc_nlp_not_used call and additional set_state in the completion routine. Remove the lpfc_nlp_set_state post issue_logo. Isn't necessary. Link: https://lore.kernel.org/r/20210412013127.2387-3-jsmart2021@gmail.comCo-developed-by: Justin Tee <justin.tee@broadcom.com> Signed-off-by: Justin Tee <justin.tee@broadcom.com> Signed-off-by: James Smart <jsmart2021@gmail.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
fffd18ec