Commit 00707e4c authored by Miquel Raynal's avatar Miquel Raynal Committed by Eduardo Valentin

thermal: armada: remove sensors validity from the IP initialization

When using new bindings with multiple sensors, sensor validity is
checked twice because sensor selection also checks for the validity.

Remove the redundant call from the IP initialization helper and move it
to the legacy probe section where it is still needed.
Signed-off-by: default avatarMiquel Raynal <miquel.raynal@bootlin.com>
Signed-off-by: default avatarEduardo Valentin <edubezval@gmail.com>
parent f7c2068a
......@@ -222,9 +222,6 @@ static void armada380_init(struct platform_device *pdev,
reg &= ~CONTROL0_TSEN_TC_TRIM_MASK;
reg |= CONTROL0_TSEN_TC_TRIM_VAL;
regmap_write(priv->syscon, data->syscon_control0_off, reg);
/* Wait the sensors to be valid or the core will warn the user */
armada_wait_sensor_validity(priv);
}
static void armada_ap806_init(struct platform_device *pdev,
......@@ -244,9 +241,6 @@ static void armada_ap806_init(struct platform_device *pdev,
reg &= ~CONTROL0_TSEN_AVG_BYPASS;
regmap_write(priv->syscon, data->syscon_control0_off, reg);
/* Wait the sensors to be valid or the core will warn the user */
armada_wait_sensor_validity(priv);
}
static void armada_cp110_init(struct platform_device *pdev,
......@@ -652,6 +646,9 @@ static int armada_thermal_probe(struct platform_device *pdev)
priv->data->init(pdev, priv);
/* Wait the sensors to be valid */
armada_wait_sensor_validity(priv);
tz = thermal_zone_device_register(priv->zone_name, 0, 0, priv,
&legacy_ops, NULL, 0, 0);
if (IS_ERR(tz)) {
......