mmc: dw_mmc: Don't start commands while busy
We've seen problems on some WiFi modules where we seem to send a CMD53 (which requires the data lines) while the module is asserting busy. We shouldn't do that. The Designware Databook says that before issuing a new data transfer command we should check for busy, so that's what we'll do. We'll leverage the existing dw_mmc knowledge about whether it should wait for the previous command to finish to know whether we should check for busy before sending the command. This means we won't end up incorrectly waiting for things like CMD52 (SDIO) or CMD13 (SD) which don't use the data line. Note that this also has the advantage of making sure that we don't change the clock while the card is busy, too. Signed-off-by: Doug Anderson <dianders@chromium.org> Tested-by: Javier Martinez Canillas <javier.martinez@collabora.co.uk> Signed-off-by: Jaehoon Chung <jh80.chung@samsung.com> Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>