Commit 10938a08 authored by Miquel Raynal's avatar Miquel Raynal

mtd: rawnand: arasan: Workaround a misbehaving prog type with NV-DDR

As explained in the comment introduced above the fix, the Arasan
controller driver starts an operation when the prog register is being
written with a "type" specific to the action to perform.

The prog type used until now to perform a CHANGE READ COLUMN with an SDR
interface was the PAGE READ type (CMD + ADDR + CMD +
DATA). Unfortunately, for an unknown reason (let's call this a silicon
bug) any CHANGE READ COLUMN performed this way in NV-DDR mode will fail:
the data ready flag will never be triggered, nor will be the transfer
complete flag. Forcefully, this leads to a timeout situation which is
not easy to handle.

Fortunately, it was spotted that sending the same commands through a
different prog register "type", CHANGE READ COLUMN ENHANCED, would work
all the time (even though this particular command is not supported by
the core and is only available in a limited set of devices - we only
care about the controller configuration and not the actual command which
is sent to the device). So let's use this type instead when a CHANGE
READ COLUMN is requested.
Signed-off-by: default avatarMiquel Raynal <miquel.raynal@bootlin.com>
Link: https://lore.kernel.org/linux-mtd/20210505213750.257417-22-miquel.raynal@bootlin.com
parent 698ddeb8
......@@ -53,6 +53,7 @@
#define PROG_RST BIT(8)
#define PROG_GET_FEATURE BIT(9)
#define PROG_SET_FEATURE BIT(10)
#define PROG_CHG_RD_COL_ENH BIT(14)
#define INTR_STS_EN_REG 0x14
#define INTR_SIG_EN_REG 0x18
......@@ -622,7 +623,23 @@ static int anfc_param_read_type_exec(struct nand_chip *chip,
static int anfc_data_read_type_exec(struct nand_chip *chip,
const struct nand_subop *subop)
{
return anfc_misc_data_type_exec(chip, subop, PROG_PGRD);
u32 prog_reg = PROG_PGRD;
/*
* Experience shows that while in SDR mode sending a CHANGE READ COLUMN
* command through the READ PAGE "type" always works fine, when in
* NV-DDR mode the same command simply fails. However, it was also
* spotted that any CHANGE READ COLUMN command sent through the CHANGE
* READ COLUMN ENHANCED "type" would correctly work in both cases (SDR
* and NV-DDR). So, for simplicity, let's program the controller with
* the CHANGE READ COLUMN ENHANCED "type" whenever we are requested to
* perform a CHANGE READ COLUMN operation.
*/
if (subop->instrs[0].ctx.cmd.opcode == NAND_CMD_RNDOUT &&
subop->instrs[2].ctx.cmd.opcode == NAND_CMD_RNDOUTSTART)
prog_reg = PROG_CHG_RD_COL_ENH;
return anfc_misc_data_type_exec(chip, subop, prog_reg);
}
static int anfc_param_write_type_exec(struct nand_chip *chip,
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!