iio: temperature: mlx90632 Add runtime powermanagement modes
The sensor can operate in lower power modes and even make measurements when in those lower powered modes. The decision was taken that if measurement is not requested within 2 seconds the sensor will remain in SLEEP_STEP power mode, where measurements are triggered on request with setting the start of measurement bit (SOB). In this mode the measurements are taking a bit longer because we need to start it and complete it. Currently, in continuous mode we read ready data and this mode is activated if sensor measurement is requested within 2 seconds. The suspend timeout is increased to 6 seconds (instead of 3 before), because that enables more measurements in lower power mode (SLEEP_STEP), with the lowest refresh rate (2 seconds). Signed-off-by: Crt Mori <cmo@melexis.com> Link: https://lore.kernel.org/r/be405068f081f2d518843897b13cd0289c280b5d.1663834141.git.cmo@melexis.comSigned-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>