Commit 33159378 authored by Clemens Ladisch's avatar Clemens Ladisch Committed by Jaroslav Kysela

[ALSA] usb-audio: fix non-48k sample rates with SB Audigy 2 ZS

Modules: USB generic driver

On the Audigy 2 ZS, disable all sample rate that are not a multiple of
48 kHz because the others work only with the digital output which is
not yet supported.
Signed-off-by: default avatarClemens Ladisch <clemens@ladisch.de>
parent fc80a202
......@@ -2493,12 +2493,13 @@ static int parse_audio_format(struct snd_usb_audio *chip, struct audioformat *fp
if (err < 0)
return err;
#if 1
/* FIXME: temporary hack for extigy/audigy 2 nx */
/* FIXME: temporary hack for extigy/audigy 2 nx/zs */
/* extigy apparently supports sample rates other than 48k
* but not in ordinary way. so we enable only 48k atm.
*/
if (chip->usb_id == USB_ID(0x041e, 0x3000) ||
chip->usb_id == USB_ID(0x041e, 0x3020)) {
chip->usb_id == USB_ID(0x041e, 0x3020) ||
chip->usb_id == USB_ID(0x041e, 0x3061)) {
if (fmt[3] == USB_FORMAT_TYPE_I &&
fp->rates != SNDRV_PCM_RATE_48000 &&
fp->rates != SNDRV_PCM_RATE_96000)
......