Commit 39712e8b authored by Johan Hovold's avatar Johan Hovold

USB: serial: ti_usb_3410_5052: fix control-message error handling

Make sure to detect and return an error on zero-length control-message
transfers when reading from the device.

This addresses a potential failure to detect an empty transmit buffer
during close.

Also remove a redundant check for short transfer when sending a command.

Fixes: 1da177e4 ("Linux-2.6.12-rc2")
Reviewed-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Signed-off-by: default avatarJohan Hovold <johan@kernel.org>
parent 1eac5c24
...@@ -1553,13 +1553,10 @@ static int ti_command_out_sync(struct ti_device *tdev, __u8 command, ...@@ -1553,13 +1553,10 @@ static int ti_command_out_sync(struct ti_device *tdev, __u8 command,
(USB_TYPE_VENDOR | USB_RECIP_DEVICE | USB_DIR_OUT), (USB_TYPE_VENDOR | USB_RECIP_DEVICE | USB_DIR_OUT),
value, moduleid, data, size, 1000); value, moduleid, data, size, 1000);
if (status == size) if (status < 0)
status = 0; return status;
if (status > 0)
status = -ECOMM;
return status; return 0;
} }
...@@ -1575,8 +1572,7 @@ static int ti_command_in_sync(struct ti_device *tdev, __u8 command, ...@@ -1575,8 +1572,7 @@ static int ti_command_in_sync(struct ti_device *tdev, __u8 command,
if (status == size) if (status == size)
status = 0; status = 0;
else if (status >= 0)
if (status > 0)
status = -ECOMM; status = -ECOMM;
return status; return status;
......