Commit 3e2e9cf9 authored by Nicholas Mc Guire's avatar Nicholas Mc Guire Committed by Greg Kroah-Hartman

staging: fieldbus: anybus-s: fix wait_for_completion_timeout return handling

wait_for_completion_timeout() returns unsigned long (0 on timeout or
remaining jiffies) not int. Assigning this return value to int may
theoretically overflow (though not in this case where TIMEOUT is
only HZ*2).

Fix this inconsistency by wrapping the wait_for_completion_timeout
into the if().
Signed-off-by: default avatarNicholas Mc Guire <hofrat@osadl.org>
Reviewed-by: default avatarSven Van Asbroeck <TheSven73@gmail.com>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
parent 91b6cb72
......@@ -1325,11 +1325,10 @@ anybuss_host_common_probe(struct device *dev,
* interrupt came in: ready to go !
*/
reset_deassert(cd);
ret = wait_for_completion_timeout(&cd->card_boot, TIMEOUT);
if (ret == 0)
if (!wait_for_completion_timeout(&cd->card_boot, TIMEOUT)) {
ret = -ETIMEDOUT;
if (ret < 0)
goto err_reset;
}
/*
* according to the anybus docs, we're allowed to read these
* without handshaking / reserving the area
......