Commit 3f2cde74 authored by Christophe JAILLET's avatar Christophe JAILLET Committed by Jonathan Cameron

iio: magnetometer: mmc35240: Fix a typo in the name of a constant

Everything is about mmc35240_ except MMC53240_WAIT_SET_RESET (3 and 5
switched).

This is likely a typo. Define and use MMC35240_WAIT_SET_RESET instead.
Signed-off-by: default avatarChristophe JAILLET <christophe.jaillet@wanadoo.fr>
Signed-off-by: default avatarJonathan Cameron <Jonathan.Cameron@huawei.com>
parent b4a339ba
......@@ -53,7 +53,7 @@
#define MMC35240_CTRL1_BW_SHIFT 0
#define MMC35240_WAIT_CHARGE_PUMP 50000 /* us */
#define MMC53240_WAIT_SET_RESET 1000 /* us */
#define MMC35240_WAIT_SET_RESET 1000 /* us */
/*
* Memsic OTP process code piece is put here for reference:
......@@ -225,7 +225,7 @@ static int mmc35240_init(struct mmc35240_data *data)
ret = mmc35240_hw_set(data, true);
if (ret < 0)
return ret;
usleep_range(MMC53240_WAIT_SET_RESET, MMC53240_WAIT_SET_RESET + 1);
usleep_range(MMC35240_WAIT_SET_RESET, MMC35240_WAIT_SET_RESET + 1);
ret = mmc35240_hw_set(data, false);
if (ret < 0)
......