drm/panel: simple: Fix Innolux G101ICE-L01 timings
The Innolux G101ICE-L01 datasheet [1] page 17 table 6.1 INPUT SIGNAL TIMING SPECIFICATIONS indicates that maximum vertical blanking time is 40 lines. Currently the driver uses 29 lines. Fix it, and since this panel is a DE panel, adjust the timings to make them less hostile to controllers which cannot do 1 px HSA/VSA, distribute the delays evenly between all three parts. [1] https://www.data-modul.com/sites/default/files/products/G101ICE-L01-C2-specification-12042389.pdf Fixes: 1e29b840 ("drm/panel: simple: Add Innolux G101ICE-L01 panel") Signed-off-by: Marek Vasut <marex@denx.de> Reviewed-by: Neil Armstrong <neil.armstrong@linaro.org> Link: https://patchwork.freedesktop.org/patch/msgid/20231008223256.279196-1-marex@denx.de