Commit 41761299 authored by Stanley Chu's avatar Stanley Chu Committed by Greg Kroah-Hartman

scsi: ufs: Avoid configuring regulator with undefined voltage range

[ Upstream commit 3b141e8c ]

For regulators used by UFS, vcc, vccq and vccq2 will have voltage range
initialized by ufshcd_populate_vreg(), however other regulators may have
undefined voltage range if dt-bindings have no such definition.

In above undefined case, both "min_uV" and "max_uV" fields in ufs_vreg
struct will be zero values and these values will be configured on
regulators in different power modes.

Currently this may have no harm if both "min_uV" and "max_uV" always keep
"zero values" because regulator_set_voltage() will always bypass such
invalid values and return "good" results.

However improper values shall be fixed to avoid potential bugs.  Simply
bypass voltage configuration if voltage range is not defined.
Signed-off-by: default avatarStanley Chu <stanley.chu@mediatek.com>
Reviewed-by: default avatarAvri Altman <avri.altman@wdc.com>
Acked-by: default avatarAlim Akhtar <alim.akhtar@samsung.com>
Signed-off-by: default avatarMartin K. Petersen <martin.petersen@oracle.com>
Signed-off-by: default avatarSasha Levin <sashal@kernel.org>
parent 75246f57
......@@ -5504,12 +5504,15 @@ static int ufshcd_config_vreg(struct device *dev,
name = vreg->name;
if (regulator_count_voltages(reg) > 0) {
min_uV = on ? vreg->min_uV : 0;
ret = regulator_set_voltage(reg, min_uV, vreg->max_uV);
if (ret) {
dev_err(dev, "%s: %s set voltage failed, err=%d\n",
if (vreg->min_uV && vreg->max_uV) {
min_uV = on ? vreg->min_uV : 0;
ret = regulator_set_voltage(reg, min_uV, vreg->max_uV);
if (ret) {
dev_err(dev,
"%s: %s set voltage failed, err=%d\n",
__func__, name, ret);
goto out;
goto out;
}
}
uA_load = on ? vreg->max_uA : 0;
......