staging: comedi: usbduxsigma: don't clobber ai_timer in command test
`devpriv->ai_timer` is used while an asynchronous command is running on the AI subdevice. It also gets modified by the subdevice's `cmdtest` handler for checking new asynchronous commands (`usbduxsigma_ai_cmdtest()`), which is not correct as it's allowed to check new commands while an old command is still running. Fix it by moving the code which sets up `devpriv->ai_timer` and `devpriv->ai_interval` into the subdevice's `cmd` handler, `usbduxsigma_ai_cmd()`. Note that the removed code in `usbduxsigma_ai_cmdtest()` checked that `devpriv->ai_timer` did not end up less than than 1, but that could not happen because `cmd->scan_begin_arg` had already been checked to be at least the minimum required value (at least when `cmd->scan_begin_src == TRIG_TIMER`, which had also been checked to be the case). Fixes: b986be85 ("staging: comedi: usbduxsigma: tidy up analog input command support) Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Reviewed-by: Bernd Porr <mail@berndporr.me.uk> Reviewed-by: H Hartley Sweeten <hsweeten@visionengravers.com> Cc: <stable@vger.kernel.org> # 3.19 onwards Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Showing