Commit 44c7b80b authored by Qais Yousef's avatar Qais Yousef Committed by Peter Zijlstra

sched/fair: Detect capacity inversion

Check each performance domain to see if thermal pressure is causing its
capacity to be lower than another performance domain.

We assume that each performance domain has CPUs with the same
capacities, which is similar to an assumption made in energy_model.c

We also assume that thermal pressure impacts all CPUs in a performance
domain equally.

If there're multiple performance domains with the same capacity_orig, we
will trigger a capacity inversion if the domain is under thermal
pressure.

The new cpu_in_capacity_inversion() should help users to know when
information about capacity_orig are not reliable and can opt in to use
the inverted capacity as the 'actual' capacity_orig.
Signed-off-by: default avatarQais Yousef <qais.yousef@arm.com>
Signed-off-by: default avatarPeter Zijlstra (Intel) <peterz@infradead.org>
Link: https://lore.kernel.org/r/20220804143609.515789-9-qais.yousef@arm.com
parent d81304bc
......@@ -8824,16 +8824,73 @@ static unsigned long scale_rt_capacity(int cpu)
static void update_cpu_capacity(struct sched_domain *sd, int cpu)
{
unsigned long capacity_orig = arch_scale_cpu_capacity(cpu);
unsigned long capacity = scale_rt_capacity(cpu);
struct sched_group *sdg = sd->groups;
struct rq *rq = cpu_rq(cpu);
cpu_rq(cpu)->cpu_capacity_orig = arch_scale_cpu_capacity(cpu);
rq->cpu_capacity_orig = capacity_orig;
if (!capacity)
capacity = 1;
cpu_rq(cpu)->cpu_capacity = capacity;
trace_sched_cpu_capacity_tp(cpu_rq(cpu));
rq->cpu_capacity = capacity;
/*
* Detect if the performance domain is in capacity inversion state.
*
* Capacity inversion happens when another perf domain with equal or
* lower capacity_orig_of() ends up having higher capacity than this
* domain after subtracting thermal pressure.
*
* We only take into account thermal pressure in this detection as it's
* the only metric that actually results in *real* reduction of
* capacity due to performance points (OPPs) being dropped/become
* unreachable due to thermal throttling.
*
* We assume:
* * That all cpus in a perf domain have the same capacity_orig
* (same uArch).
* * Thermal pressure will impact all cpus in this perf domain
* equally.
*/
if (static_branch_unlikely(&sched_asym_cpucapacity)) {
unsigned long inv_cap = capacity_orig - thermal_load_avg(rq);
struct perf_domain *pd = rcu_dereference(rq->rd->pd);
rq->cpu_capacity_inverted = 0;
for (; pd; pd = pd->next) {
struct cpumask *pd_span = perf_domain_span(pd);
unsigned long pd_cap_orig, pd_cap;
cpu = cpumask_any(pd_span);
pd_cap_orig = arch_scale_cpu_capacity(cpu);
if (capacity_orig < pd_cap_orig)
continue;
/*
* handle the case of multiple perf domains have the
* same capacity_orig but one of them is under higher
* thermal pressure. We record it as capacity
* inversion.
*/
if (capacity_orig == pd_cap_orig) {
pd_cap = pd_cap_orig - thermal_load_avg(cpu_rq(cpu));
if (pd_cap > inv_cap) {
rq->cpu_capacity_inverted = inv_cap;
break;
}
} else if (pd_cap_orig > inv_cap) {
rq->cpu_capacity_inverted = inv_cap;
break;
}
}
}
trace_sched_cpu_capacity_tp(rq);
sdg->sgc->capacity = capacity;
sdg->sgc->min_capacity = capacity;
......
......@@ -1041,6 +1041,7 @@ struct rq {
unsigned long cpu_capacity;
unsigned long cpu_capacity_orig;
unsigned long cpu_capacity_inverted;
struct balance_callback *balance_callback;
......@@ -2878,6 +2879,24 @@ static inline unsigned long capacity_orig_of(int cpu)
return cpu_rq(cpu)->cpu_capacity_orig;
}
/*
* Returns inverted capacity if the CPU is in capacity inversion state.
* 0 otherwise.
*
* Capacity inversion detection only considers thermal impact where actual
* performance points (OPPs) gets dropped.
*
* Capacity inversion state happens when another performance domain that has
* equal or lower capacity_orig_of() becomes effectively larger than the perf
* domain this CPU belongs to due to thermal pressure throttling it hard.
*
* See comment in update_cpu_capacity().
*/
static inline unsigned long cpu_in_capacity_inversion(int cpu)
{
return cpu_rq(cpu)->cpu_capacity_inverted;
}
/**
* enum cpu_util_type - CPU utilization type
* @FREQUENCY_UTIL: Utilization used to select frequency
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment