Commit 48657d22 authored by Michael Holzheu's avatar Michael Holzheu Committed by Martin Schwidefsky

[S390] Use diag308 subcodes 3 and 6 for reboot and dump when possible.

This patch fixes a problem with the following scenario:
 1. Linux booted from DASD "A"
 2. Reboot from DASD "B" using "/sys/firmware/reipl/ccw/device"
 3. Reboot DASD "B"
Without this patch in step 3 on newer s390 systems under LPAR instead of
DASD "B", DASD "A" will be booted. The reason is that in step 2 we use CCW
reipl and in step 3 we use DIAG308 (subcode 3) reipl. DIAG308 does not
notice the CCW reipl and still thinks that it has to reboot DASD "A".
Before applying this fix, ensure to have MCF RJ9967101E or z9 GA3 base driver
installed.
Signed-off-by: default avatarMichael Holzheu <holzheu@de.ibm.com>
Signed-off-by: default avatarMartin Schwidefsky <schwidefsky@de.ibm.com>
parent a2fd64d6
......@@ -595,7 +595,9 @@ static int reipl_set_type(enum ipl_type type)
switch(type) {
case IPL_TYPE_CCW:
if (MACHINE_IS_VM)
if (diag308_set_works)
reipl_method = REIPL_METHOD_CCW_DIAG;
else if (MACHINE_IS_VM)
reipl_method = REIPL_METHOD_CCW_VM;
else
reipl_method = REIPL_METHOD_CCW_CIO;
......@@ -659,8 +661,6 @@ void reipl_run(struct shutdown_trigger *trigger)
switch (reipl_method) {
case REIPL_METHOD_CCW_CIO:
devid.devno = reipl_block_ccw->ipl_info.ccw.devno;
if (ipl_info.type == IPL_TYPE_CCW && devid.devno == ipl_devno)
diag308(DIAG308_IPL, NULL);
devid.ssid = 0;
reipl_ccw_dev(&devid);
break;
......@@ -745,6 +745,7 @@ static int __init reipl_ccw_init(void)
reipl_block_ccw->hdr.version = IPL_PARM_BLOCK_VERSION;
reipl_block_ccw->hdr.blk0_len = IPL_PARM_BLK0_CCW_LEN;
reipl_block_ccw->hdr.pbt = DIAG308_IPL_TYPE_CCW;
reipl_block_ccw->hdr.flags = DIAG308_FLAGS_LP_VALID;
/* check if read scp info worked and set loadparm */
if (sclp_ipl_info.is_valid)
memcpy(reipl_block_ccw->ipl_info.ccw.load_param,
......@@ -753,8 +754,7 @@ static int __init reipl_ccw_init(void)
/* read scp info failed: set empty loadparm (EBCDIC blanks) */
memset(reipl_block_ccw->ipl_info.ccw.load_param, 0x40,
LOADPARM_LEN);
/* FIXME: check for diag308_set_works when enabling diag ccw reipl */
if (!MACHINE_IS_VM)
if (!MACHINE_IS_VM && !diag308_set_works)
sys_reipl_ccw_loadparm_attr.attr.mode = S_IRUGO;
if (ipl_info.type == IPL_TYPE_CCW)
reipl_block_ccw->ipl_info.ccw.devno = ipl_devno;
......@@ -876,7 +876,9 @@ static int dump_set_type(enum dump_type type)
return -EINVAL;
switch (type) {
case DUMP_TYPE_CCW:
if (MACHINE_IS_VM)
if (diag308_set_works)
dump_method = DUMP_METHOD_CCW_DIAG;
else if (MACHINE_IS_VM)
dump_method = DUMP_METHOD_CCW_VM;
else
dump_method = DUMP_METHOD_CCW_CIO;
......
......@@ -143,6 +143,10 @@ enum diag308_opt {
DIAG308_IPL_OPT_DUMP = 0x20,
};
enum diag308_flags {
DIAG308_FLAGS_LP_VALID = 0x80,
};
enum diag308_rc {
DIAG308_RC_OK = 1,
};
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment