ARM: dts: lpc32xx: Revert set default clock rate of HCLK PLL
This reverts commit c17e9377. The lpc32xx clock driver is not able to actually change the PLL rate as this would require reparenting ARM_CLK, DDRAM_CLK, PERIPH_CLK to SYSCLK, then stop the PLL, update the register, restart the PLL and wait for the PLL to lock and finally reparent ARM_CLK, DDRAM_CLK, PERIPH_CLK to HCLK PLL. Currently, the HCLK driver simply updates the registers but this has no real effect and all the clock rate calculation end up being wrong. This is especially annoying for the peripheral (e.g. UARTs, I2C, SPI). Signed-off-by: Alexandre Belloni <alexandre.belloni@bootlin.com> Tested-by: Gregory CLEMENT <gregory.clement@bootlin.com> Link: https://lore.kernel.org/r/20210203090320.GA3760268@piout.net' Signed-off-by: Arnd Bergmann <arnd@arndb.de>