hwmon: (aquacomputer_d5next) Add selective 200ms delay after sending ctrl report
Add a 200ms delay after sending a ctrl report to Quadro, Octo, D5 Next and Aquaero to give them enough time to process the request and save the data to memory. Otherwise, under heavier userspace loads where multiple sysfs entries are usually set in quick succession, a new ctrl report could be requested from the device while it's still processing the previous one and fail with -EPIPE. The delay is only applied if two ctrl report operations are near each other in time. Reported by a user on Github [1] and tested by both of us. [1] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/issues/82 Fixes: 752b9279 ("hwmon: (aquacomputer_d5next) Add support for Aquacomputer Octo") Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com> Link: https://lore.kernel.org/r/20230807172004.456968-1-savicaleksa83@gmail.comSigned-off-by: Guenter Roeck <linux@roeck-us.net>