Commit 57aac7c5 authored by Ashok Nagarajan's avatar Ashok Nagarajan Committed by John W. Linville

mac80211: Implement HT mixed protection mode

Section 9.23.3.5 of IEEE 80211s standard describes the protection rules for
HT mesh STA in a MBSS. Three HT protection modes are supported for now:

non-HT mixed mode - is selected if any non-HT peers are present in our MBSS.
20MHz-protection mode - is selected if all peers in our 20/40MHz MBSS support
			HT and atleast one HT20 peer is present.
no-protection mode - is selected otherwise.

This is a limited implementation of 9.23.3.5, which only considers mesh peers
when determining the HT protection mode. Station's channel_type needs to be
maintained.
Signed-off-by: default avatarAshok Nagarajan <ashok@cozybit.com>
Reviewed-by: default avatarThomas Pedersen <thomas@cozybit.com>
Signed-off-by: default avatarJohn W. Linville <linville@tuxdriver.com>
parent 431e3154
......@@ -105,6 +105,66 @@ static struct sta_info *mesh_plink_alloc(struct ieee80211_sub_if_data *sdata,
return sta;
}
/** mesh_set_ht_prot_mode - set correct HT protection mode
*
* Section 9.23.3.5 of IEEE 80211s standard describes the protection rules for
* HT mesh STA in a MBSS. Three HT protection modes are supported for now,
* non-HT mixed mode, 20MHz-protection and no-protection mode. non-HT mixed
* mode is selected if any non-HT peers are present in our MBSS.
* 20MHz-protection mode is selected if all peers in our 20/40MHz MBSS support
* HT and atleast one HT20 peer is present. Otherwise no-protection mode is
* selected.
*/
static u32 mesh_set_ht_prot_mode(struct ieee80211_sub_if_data *sdata)
{
struct ieee80211_local *local = sdata->local;
struct sta_info *sta;
u32 changed = 0;
u16 ht_opmode;
bool non_ht_sta = false, ht20_sta = false;
if (local->_oper_channel_type == NL80211_CHAN_NO_HT)
return 0;
rcu_read_lock();
list_for_each_entry_rcu(sta, &local->sta_list, list) {
if (sdata == sta->sdata &&
sta->plink_state == NL80211_PLINK_ESTAB) {
switch (sta->ch_type) {
case NL80211_CHAN_NO_HT:
mpl_dbg("mesh_plink %pM: nonHT sta (%pM) is present",
sdata->vif.addr, sta->sta.addr);
non_ht_sta = true;
goto out;
case NL80211_CHAN_HT20:
mpl_dbg("mesh_plink %pM: HT20 sta (%pM) is present",
sdata->vif.addr, sta->sta.addr);
ht20_sta = true;
default:
break;
}
}
}
out:
rcu_read_unlock();
if (non_ht_sta)
ht_opmode = IEEE80211_HT_OP_MODE_PROTECTION_NONHT_MIXED;
else if (ht20_sta && local->_oper_channel_type > NL80211_CHAN_HT20)
ht_opmode = IEEE80211_HT_OP_MODE_PROTECTION_20MHZ;
else
ht_opmode = IEEE80211_HT_OP_MODE_PROTECTION_NONE;
if (sdata->vif.bss_conf.ht_operation_mode != ht_opmode) {
sdata->vif.bss_conf.ht_operation_mode = ht_opmode;
changed = BSS_CHANGED_HT;
mpl_dbg("mesh_plink %pM: protection mode changed to %d",
sdata->vif.addr, ht_opmode);
}
return changed;
}
/**
* __mesh_plink_deactivate - deactivate mesh peer link
*
......@@ -302,11 +362,14 @@ static struct sta_info *mesh_peer_init(struct ieee80211_sub_if_data *sdata,
else
memset(&sta->sta.ht_cap, 0, sizeof(sta->sta.ht_cap));
if (elems->ht_operation)
if (elems->ht_operation) {
if (!(elems->ht_operation->ht_param &
IEEE80211_HT_PARAM_CHAN_WIDTH_ANY))
sta->sta.ht_cap.cap &=
~IEEE80211_HT_CAP_SUP_WIDTH_20_40;
sta->ch_type =
ieee80211_ht_oper_to_channel_type(elems->ht_operation);
}
rate_control_rate_init(sta);
spin_unlock_bh(&sta->lock);
......@@ -495,9 +558,10 @@ void mesh_rx_plink_frame(struct ieee80211_sub_if_data *sdata, struct ieee80211_m
enum plink_event event;
enum ieee80211_self_protected_actioncode ftype;
size_t baselen;
bool deactivated, matches_local = true;
bool matches_local = true;
u8 ie_len;
u8 *baseaddr;
u32 changed = 0;
__le16 plid, llid, reason;
#ifdef CONFIG_MAC80211_VERBOSE_MPL_DEBUG
static const char *mplstates[] = {
......@@ -783,7 +847,8 @@ void mesh_rx_plink_frame(struct ieee80211_sub_if_data *sdata, struct ieee80211_m
sta->plink_state = NL80211_PLINK_ESTAB;
spin_unlock_bh(&sta->lock);
mesh_plink_inc_estab_count(sdata);
ieee80211_bss_info_change_notify(sdata, BSS_CHANGED_BEACON);
changed |= mesh_set_ht_prot_mode(sdata);
changed |= BSS_CHANGED_BEACON;
mpl_dbg("Mesh plink with %pM ESTABLISHED\n",
sta->sta.addr);
break;
......@@ -818,7 +883,8 @@ void mesh_rx_plink_frame(struct ieee80211_sub_if_data *sdata, struct ieee80211_m
sta->plink_state = NL80211_PLINK_ESTAB;
spin_unlock_bh(&sta->lock);
mesh_plink_inc_estab_count(sdata);
ieee80211_bss_info_change_notify(sdata, BSS_CHANGED_BEACON);
changed |= mesh_set_ht_prot_mode(sdata);
changed |= BSS_CHANGED_BEACON;
mpl_dbg("Mesh plink with %pM ESTABLISHED\n",
sta->sta.addr);
mesh_plink_frame_tx(sdata,
......@@ -836,13 +902,13 @@ void mesh_rx_plink_frame(struct ieee80211_sub_if_data *sdata, struct ieee80211_m
case CLS_ACPT:
reason = cpu_to_le16(WLAN_REASON_MESH_CLOSE);
sta->reason = reason;
deactivated = __mesh_plink_deactivate(sta);
__mesh_plink_deactivate(sta);
sta->plink_state = NL80211_PLINK_HOLDING;
llid = sta->llid;
mod_plink_timer(sta, dot11MeshHoldingTimeout(sdata));
spin_unlock_bh(&sta->lock);
if (deactivated)
ieee80211_bss_info_change_notify(sdata, BSS_CHANGED_BEACON);
changed |= mesh_set_ht_prot_mode(sdata);
changed |= BSS_CHANGED_BEACON;
mesh_plink_frame_tx(sdata, WLAN_SP_MESH_PEERING_CLOSE,
sta->sta.addr, llid, plid, reason);
break;
......@@ -889,4 +955,7 @@ void mesh_rx_plink_frame(struct ieee80211_sub_if_data *sdata, struct ieee80211_m
}
rcu_read_unlock();
if (changed)
ieee80211_bss_info_change_notify(sdata, changed);
}
......@@ -362,6 +362,7 @@ struct sta_info {
struct timer_list plink_timer;
s64 t_offset;
s64 t_offset_setpoint;
enum nl80211_channel_type ch_type;
#endif
#ifdef CONFIG_MAC80211_DEBUGFS
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment