Commit 585a60f2 authored by Stefan Agner's avatar Stefan Agner Committed by Shawn Guo

clk: imx: return correct frequency for Ethernet PLL

The i.MX 7 designs Ethernet PLL provides a 1000MHz reference clock.
Store the reference clock in the clk_pllv3 structure according to
the PLL type.
Signed-off-by: default avatarStefan Agner <stefan@agner.ch>
Signed-off-by: default avatarShawn Guo <shawnguo@kernel.org>
parent 69c542e8
......@@ -44,6 +44,7 @@ struct clk_pllv3 {
u32 powerdown;
u32 div_mask;
u32 div_shift;
unsigned long ref_clock;
};
#define to_clk_pllv3(_hw) container_of(_hw, struct clk_pllv3, hw)
......@@ -286,7 +287,9 @@ static const struct clk_ops clk_pllv3_av_ops = {
static unsigned long clk_pllv3_enet_recalc_rate(struct clk_hw *hw,
unsigned long parent_rate)
{
return 500000000;
struct clk_pllv3 *pll = to_clk_pllv3(hw);
return pll->ref_clock;
}
static const struct clk_ops clk_pllv3_enet_ops = {
......@@ -326,7 +329,11 @@ struct clk *imx_clk_pllv3(enum imx_pllv3_type type, const char *name,
break;
case IMX_PLLV3_ENET_IMX7:
pll->powerdown = IMX7_ENET_PLL_POWER;
pll->ref_clock = 1000000000;
ops = &clk_pllv3_enet_ops;
break;
case IMX_PLLV3_ENET:
pll->ref_clock = 500000000;
ops = &clk_pllv3_enet_ops;
break;
default:
......
Markdown is supported