Commit 589b1f7e authored by YueHaibing's avatar YueHaibing Committed by Michael Ellerman

powerpc/xics: Add missing of_node_put() in error path

The device node obtained with of_find_compatible_node() should be
released by calling of_node_put().  But it was not released when
of_get_property() failed.
Signed-off-by: default avatarYueHaibing <yuehaibing@huawei.com>
[mpe: Invert the sense of the if so we only need one return path]
Signed-off-by: default avatarMichael Ellerman <mpe@ellerman.id.au>
parent c5cbde2d
......@@ -446,10 +446,11 @@ static void __init xics_get_server_size(void)
np = of_find_compatible_node(NULL, NULL, "ibm,ppc-xics");
if (!np)
return;
isize = of_get_property(np, "ibm,interrupt-server#-size", NULL);
if (!isize)
return;
xics_interrupt_server_size = be32_to_cpu(*isize);
if (isize)
xics_interrupt_server_size = be32_to_cpu(*isize);
of_node_put(np);
}
......