Commit 5c72263e authored by Kees Cook's avatar Kees Cook

signal: HANDLER_EXIT should clear SIGNAL_UNKILLABLE

Fatal SIGSYS signals (i.e. seccomp RET_KILL_* syscall filter actions)
were not being delivered to ptraced pid namespace init processes. Make
sure the SIGNAL_UNKILLABLE doesn't get set for these cases.
Reported-by: default avatarRobert Święcki <robert@swiecki.net>
Suggested-by: default avatar"Eric W. Biederman" <ebiederm@xmission.com>
Fixes: 00b06da2 ("signal: Add SA_IMMUTABLE to ensure forced siganls do not get changed")
Cc: stable@vger.kernel.org
Signed-off-by: default avatarKees Cook <keescook@chromium.org>
Reviewed-by: default avatar"Eric W. Biederman" <ebiederm@xmission.com>
Link: https://lore.kernel.org/lkml/878rui8u4a.fsf@email.froward.int.ebiederm.org
parent 26291c54
......@@ -1342,9 +1342,10 @@ force_sig_info_to_task(struct kernel_siginfo *info, struct task_struct *t,
}
/*
* Don't clear SIGNAL_UNKILLABLE for traced tasks, users won't expect
* debugging to leave init killable.
* debugging to leave init killable. But HANDLER_EXIT is always fatal.
*/
if (action->sa.sa_handler == SIG_DFL && !t->ptrace)
if (action->sa.sa_handler == SIG_DFL &&
(!t->ptrace || (handler == HANDLER_EXIT)))
t->signal->flags &= ~SIGNAL_UNKILLABLE;
ret = send_signal(sig, info, t, PIDTYPE_PID);
spin_unlock_irqrestore(&t->sighand->siglock, flags);
......