net/mlx4_en: Choose time-stamping shift value according to HW frequency
[ Upstream commit 31c128b6 ] Previously, the shift value used for time-stamping was constant and didn't depend on the HW chip frequency. Change that to take the frequency into account and calculate the maximal value in cycles per wraparound of ten seconds. This time slot was chosen since it gives a good accuracy in time synchronization. Algorithm for shift value calculation: * Round up the maximal value in cycles to nearest power of two * Calculate maximal multiplier by division of all 64 bits set to above result * Then, invert the function clocksource_khz2mult() to get the shift from maximal mult value Fixes: ec693d47 ('net/mlx4_en: Add HW timestamping (TS) support') Signed-off-by: Eugenia Emantayev <eugenia@mellanox.com> Reviewed-by: Matan Barak <matanb@mellanox.com> Signed-off-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net> Signed-off-by: Sasha Levin <sasha.levin@oracle.com>