serial: mvebu-uart: implement support for baudrates higher than 230400 Bd
Implement simple usage of fractional divisor. When main divisor D is too large to represent requested baudrate then use divisor M from the fractional divisor feature. All the M prescalers are set to the same and maximal value 63, so the fractional part of the fractional divisor is not used at all. We also determine upper limit for possible baudrates. Experiments show that UART at baudrate 1500000 Bd with this configuration is stable. So there is no need to implement complicated calculation of fractional coefficients yet. To use this feature with higher baudrates, it is required to use UART clock provided by UART clock driver. Default boot xtal clock is not capable of higher baudrates. Reviewed-by:Marek Behún <kabel@kernel.org> Signed-off-by:
Pali Rohár <pali@kernel.org> Signed-off-by:
Marek Behún <kabel@kernel.org> Link: https://lore.kernel.org/r/20220219152818.4319-6-kabel@kernel.orgSigned-off-by:
Greg Kroah-Hartman <gregkh@linuxfoundation.org>