soundwire: qcom: adjust autoenumeration timeout
Currently timeout for autoenumeration during probe and bus reset is set to 2 secs which is really a big value. This can have an adverse effect on boot time if the slave device is not ready/reset. This was the case with wcd938x which was not reset yet but we spent 2 secs waiting in the soundwire controller probe. Reduce this time to 1/10 of Hz which should be good enough time to finish autoenumeration if any slaves are available on the bus. Reported-by: Srinivasa Rao Mandadapu <quic_srivasam@quicinc.com> Signed-off-by: Srinivas Kandagatla <srinivas.kandagatla@linaro.org> Link: https://lore.kernel.org/r/20220506084705.18525-1-srinivas.kandagatla@linaro.orgSigned-off-by: Vinod Koul <vkoul@kernel.org>