iio: hx711: add clock-frequency property in DT
Add clock-frequency property for hx711 ADC. This is the frequency of PD_SCK. After PD_SCK goes high DOUT is read just before PD_SCK goes down again. This is necessary because of parasitic capacitance on the wiring. Signed-off-by: Andreas Klinger <ak@it-klinger.de> Reviewed-by: Rob Herring <robh@kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>