iio: accel: adxl345: convert address field usage in iio_chan_spec
Currently the address field in iio_chan_spec is filled with an accel data register address for the corresponding axis. In preparation for adding calibration offset support, this sets the address field to the index of accel data registers instead of the actual register address. This change makes it easier to access both accel registers and calibration offset registers with fewer lines of code as these are located in X-axis, Y-axis, Z-axis order. Cc: Eva Rachel Retuya <eraretuya@gmail.com> Cc: Andy Shevchenko <andy.shevchenko@gmail.com> Cc: Jonathan Cameron <jic23@kernel.org> Signed-off-by: Akinobu Mita <akinobu.mita@gmail.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>