media: ir-rx51: Use 64-bit division macro

Since the PWM framework is switching struct pwm_state.period's datatype
to u64, prepare for this transition by using DIV_ROUND_CLOSEST_ULL to
handle a 64-bit dividend.

Cc: Richard Fontana <rfontana@redhat.com>
Cc: Thomas Gleixner <tglx@linutronix.de>
Cc: Kate Stewart <kstewart@linuxfoundation.org>
Cc: Allison Randal <allison@lohutok.net>
Signed-off-by: default avatarGuru Das Srinagesh <gurus@codeaurora.org>
Signed-off-by: default avatarSean Young <sean@mess.org>
Signed-off-by: default avatarMauro Carvalho Chehab <mchehab+huawei@kernel.org>
parent c77591a8
......@@ -241,7 +241,7 @@ static int ir_rx51_probe(struct platform_device *dev)
}
/* Use default, in case userspace does not set the carrier */
ir_rx51.freq = DIV_ROUND_CLOSEST(pwm_get_period(pwm), NSEC_PER_SEC);
ir_rx51.freq = DIV_ROUND_CLOSEST_ULL(pwm_get_period(pwm), NSEC_PER_SEC);
pwm_put(pwm);
hrtimer_init(&ir_rx51.timer, CLOCK_MONOTONIC, HRTIMER_MODE_REL);
......