net: socionext: reset hardware in ndo_stop
When the interface is down, head/tail of the descriptor ring address is set to 0 in netsec_netdev_stop(). But netsec hardware still keeps the previous descriptor ring address, so there is inconsistency between driver and hardware after interface is up at a later time. To address this inconsistency, add netsec_reset_hardware() when the interface is down. In addition, to minimize the reset process, add flag to decide whether driver loads the netsec microcode. Even if driver resets the netsec hardware, netsec microcode keeps resident on RAM, so it is ok we only load the microcode at initialization. This patch is critical for installation over network. Signed-off-by: Masahisa KOJIMA <masahisa.kojima@linaro.org> Fixes: 533dd11a ("net: socionext: Add Synquacer NetSec driver") Signed-off-by: Jassi Brar <jaswinder.singh@linaro.org> Signed-off-by: David S. Miller <davem@davemloft.net>