ACPICA: Fix potential infinite loop in acpi_rs_dump_byte_list
There is a potenial infinite loop if acpi_rs_dump_byte_list is called with a Length greater than 255 since the current loop counter is just a u8 and will wrap to zero and never reach the desired value in Length. Fix this by making the loop counter the size type as Length. Signed-off-by: Colin Ian King <colin.king@canonical.com> Signed-off-by: Erik Schmauss <erik.schmauss@intel.com> Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>