Commit a8168b6c authored by Michael Chan's avatar Michael Chan Committed by David S. Miller

bnxt_en: Don't print "Link speed -1 no longer supported" messages.

On some dual port NICs, the 2 ports have to be configured with compatible
link speeds.  Under some conditions, a port's configured speed may no
longer be supported.  The firmware will send a message to the driver
when this happens.

Improve this logic that prints out the warning by only printing it if
we can determine the link speed that is no longer supported.  If the
speed is unknown or it is in autoneg mode, skip the warning message.
Reported-by: default avatarThomas Bogendoerfer <tbogendoerfer@suse.de>
Signed-off-by: default avatarMichael Chan <michael.chan@broadcom.com>
Tested-by: default avatarThomas Bogendoerfer <tbogendoerfer@suse.de>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
parent 24e5992a
......@@ -1706,12 +1706,16 @@ static int bnxt_async_event_process(struct bnxt *bp,
if (BNXT_VF(bp))
goto async_event_process_exit;
if (data1 & 0x20000) {
/* print unsupported speed warning in forced speed mode only */
if (!(link_info->autoneg & BNXT_AUTONEG_SPEED) &&
(data1 & 0x20000)) {
u16 fw_speed = link_info->force_link_speed;
u32 speed = bnxt_fw_to_ethtool_speed(fw_speed);
netdev_warn(bp->dev, "Link speed %d no longer supported\n",
speed);
if (speed != SPEED_UNKNOWN)
netdev_warn(bp->dev, "Link speed %d no longer supported\n",
speed);
}
set_bit(BNXT_LINK_SPEED_CHNG_SP_EVENT, &bp->sp_event);
/* fall thru */
......